-->
This section describes the tasks that you must complete before you test an ATA/ATAPI controller by using the Windows Hardware Lab Kit (Windows HLK):
Hardware Requirements.
Software Requirements.
Test Computer Configuration.
Hardware Requirements
Download Standard SATA AHCI Controller Drivers Windows 10. Aim at and expand IDE ATA/ATAPI Controller and right click the Standard SATA AHCI Controller to Update driver. Download Standard SATA AHCI Controller Drivers Windows 10 [Solved] Kindle Fire Not Recognized on Windows 10. Top 4 Download periodically updates drivers information of ide ata atapi full drivers versions from the publishers, but some information may be slightly out-of-date. Using warez version or not proper ide ata atapi driver install is risk.
Ide Ata/atapi Controllers Driver Download
- Click the + symbol beside IDE ATA/ATAPI controllers, this would show the devices under this category. User will find the IDE storage controller driver installed. Right click on Intel ICH10 Family 4Port Serial ATA Storage Controller and click Update Driver.
- Mar 22, 2014 IDE ATA/ATAPI driver missing? I wasn't sure if I should put this here, but it is a driver problem. TRIM is enabled as per CMD check but, there is no IDE ATA/ATAPI controllers option available to choose from. Is this a problem? These drivers are located in the ControlPoint download category for your computer.
The following hardware is required for testing an ATA/ATAPI controller. You might need additional hardware if the test device offers other features. To determine whether additional hardware requirements apply, see the test description for each test that appears for the device in Windows HLK Studio.
Note
With the exception of the test computer and test controller, all hardware that is involved in the test must already have a logo.
One test computer. The test computer must meet the Windows HLK requirements. For more information, see Windows HLK Prerequisites.
If the ATA/ATAPI controller supports RAID, the following requirements apply:
Two identical ATA/ATAPI RAID controllers (the test devices), unless the test device is an integrated controller.
One ATA/ATAPI hard disk drive for each channel that the test device supports. If two controllers are required, twice as many hard disks are required. The hard disk drives must each have at least 40 gigabytes (GB).
One optical drive.
One PCI-to-PCI bridge adapter, unless any of the following conditions apply:
The RAID controllers cannot fit into PCI bridge adapters. This may occur if the controllers are integrated controllers or if the controllers can only fit into specially designed slots.
The RAID controller is designed and sold only for systems that cannot accept full height PCI-to-PCI bridge adapters, such as blade servers.
You can put one of the RAID controllers into a PCI bus slot that is already behind a PCI bridge.
If the ATA/ATAPI controller supports RAID, the following requirements apply:
One ATA/ATAPI controller (the test device).
Two UDMA-capable ATA/ATAPI hard disk drives with at least 40 GB.
One DMA-capable optical recording drive that has a minimum speed of 8x.
One blank rewritable CD.
One ATA/ATAPI tape drive.
One blank tape cartridge.
If the test device does not support boot, one bootable controller and a hard disk drive that has a minimum of 36 GB are required.
Note
To certify your product for use on servers, the test computer must support four processors and a minimum of 1 GB of RAM. These system capabilities are required to test the Rebalance, D3 State, and Multiple Processor Group functionality of the device and driver. You do not need a computer that actually has more than 64 processors to test your device. Additionally, the server system(s) being used for device or driver testing must have Server Core installed prior to testing. For more information see Windows Server Installation Options.
If you use a pool of test computers to test devices, at least one computer in the pool must contain four processors and a minimum of 1 GB of RAM. Additionally, that computer must contain the device and the driver that you want to test. If the driver is the same on all the computers in the pool, the system creates a schedule to run against all test computers.
For tests that do not include a driver to test, such as hard disk drive tests, the Windows HLK scheduler constrains the tests that validate the device's and driver's rebalance, D3 state, and multiple processor groups functionality to run on the default test computer. You must manually configure this computer to have multiple processor groups. The default computer is the first test computer in the list. Test personnel must make sure that the first test computer in the list meets the minimum hardware requirements.
Note
Except for para-virtualization drivers (as defined by the WHCP Policies and Processes document), you may not use any form of virtualization when you test physical devices and their associated drivers for server certification or signature. All virtualization products do not support the underlying functionality that is required to pass the tests that relate to multiple processor groups, device power management, device PCI functionality, and other tests.
Note
Multiple Processor Groups SettingYou must set the value for the processor group size for Hardware Lab Kit testing of Windows Server 2008 R2 and later device drivers for certification. This is done by running bcdedit in an elevated command prompt window, using the /set option.
The commands for adding the group settings and restarting are as follows:
The commands for removing the group settings and rebooting are as follows:
Note
Code Integrity Setting
The Virtualization Based Security feature (VBS) of Windows Server 2016 must be enabled using Server Manager first.
Once that has occurred, the following Registry key must be created and set:
Software Requirements
The following software is required for testing an ATA/ATAPI controller:
The drivers for the test device.
The latest Windows HLK filters or updates.
Windows symbol files. These are available from the Symbol Files website.
The current release of the Windows Driver Kit (WDK).
Ide Ata/atapi Controllers Driver Download Full
Test Computer Configuration
There are three possible configurations for testing ATA/ATAPI controllers:
If the test device is an add-in controller that supports RAID, use the Add-in RAID controller test configuration.
If the test device is an integrated controller that supports RAID, use the Integrated RAID controller test configuration.
If the test device does not support RAID, use the Non-RAID controller test configuration.
Before you test an ATA/ATAPI controller in any of the three usage scenarios, make sure that the test computer is in the ready state. If a test requires parameters to be set before the test is run, a dialog box appears for that test. Review the specific test topic for more information.
Some Windows HLK tests require user intervention. When you run tests for a submission, it is a best practice to run the automated tests in a block separately from manual tests. This prevents a manual test from interrupting completion of an automated test.
Warning
When testing storage devices, we strongly recommend that you complete all Device Fundamentals tests before starting storage tests. Storage tests will reconfigure your test device, leaving the device in a state unsuitable to support Device Fundamentals tests. The following configurations provide steps to create volume on the storage test device. This is important to complete the Device Fundamental part of testing (DevFund).
Add-in RAID controller test configuration
To configure the test computer to test an ATA/ATAPI controller in an add-in RAID configuration, follow these steps:
When the test computer is turned off, complete the following assembly steps:
Install a boot-capable controller (not the test device) and hard disk drive, if the test devices do not support boot.
Install one test controller (Controller 1).
Install a PCI-to-PCI bridge, unless one of the following items is true:
The controllers cannot fit into PCI bridge adapters. This may be true for integrated controllers or controllers that can fit only into specially designed slots.
The controller is designed and sold only for systems that cannot accept full height PCI-to-PCI bridge adapters, such as blade servers.
The controller is designed and sold only for systems that cannot accept full height PCI-to-PCI bridge adapters, such as blade servers.
Install a second, duplicate test controller (Controller 2) in the PCI-to-PCI bridge card (or in the PCI bridge if the bridge card is not required).
Attach the disks to the test devices according to the following table:
Controller type Controller 1 Controller 2 ATA RAID
One ATA hard disk drive on each supported channel
One ATA hard disk drive on each supported channel
Attach an optical drive to the system, if one is not already attached.
Turn on the test system.
Set the system BIOS to support the S3 state.
Create one 60-GB RAID array on Controller 1 and two 60-GB RAID arrays on Controller 2.
The RAID array on Controller 1 is RAID Array 1, and the RAID arrays on Controller 2 are RAID Array 2 and RAID Array 3.
Configure the RAID arrays according to the following table:
RAID levels that the test device supports RAID level for RAID Array 1 RAID level for RAID Array 2 RAID level for RAID Array 3 0 only
0
0
0
1 only
1
1
1
5 only
5
5
5
0 and 1 only
1
9
0
0 and 5 only
5
9
0
1 and 5 only
5
1
1
0, 1, and 10
10
1
0
0, 1, and 5
5
1
0
0, 1, 10, and 5
5
10
0
Install the appropriate Microsoft Windows operating system to a 36-GB NTFS volume on RAID Array 1, and then configure the computer for your test network. The test network is the network that contains the Windows HLK Studio and Windows HLK Controller. If the test controller is not bootable, install a separate hard disk drive on a bootable controller.
If you have to install the manufacturer-supplied device driver on the test computer, do this now.
Start Windows on the test computer.
Create three 4-GB partitions on RAID Array 2.
If you are testing by using a client operating system, create a 4-GB NTFS spanned volume that uses unallocated space on RAID Array 1, RAID Array 2, and RAID Array 3, as the following diagram shows:
If you are testing by using a server operating system, do the following:
Create a software RAID 1 mirror from one of the NTFS partitions on RAID Array 2 to the unallocated space on RAID Array 1, as the following diagram shows.
Create a 4-GB NTFS software RAID 5 array that uses unallocated space on RAID Array 1, RAID Array 2, and RAID Array 3, as the following diagram shows.
To set the system page file and enable crashdump, follow these steps:
Click the Start button, right-click My Computer, and then click Properties.
Click the General tab, and then note the amount of RAM that the computer contains.
Click the Advanced tab (or click Advanced system settings in the left pane for Windows Vista, Windows 7, Windows 8, Windows Server 2008, Windows Server 2008 R2 or Windows Server 2012), and then, in the Performance area, click Settings.
Note
If you are prompted to enter administrative credentials or allow the action, enter the credentials or allow the action.
Click the Advanced tab, and then, in the Virtual Memory area, click Change.
Select Custom Size, and then enter a number in the Initial size (MB) box that is larger than the size of RAM that you noted in step b.
In the Maximum size (MB) text box, enter a maximum size value that is larger than the initial size that you entered in the Initial size (MB) box. (The maximum size is typically 1.5 to 2 times the initial size.)
Click Set, and then click OK two times.
Click OK, and then restart the computer to update the page file size.
Verify that the storage array is accessible from the test computer.
Copy the Windows symbol files to %SystemDrive%Symbols.
Install the Windows HLK client application on the test computer.
Use Windows HLK Studio to create a computer pool, and then move the test computer to that pool.
Integrated RAID controller test configuration
To configure the test computer for testing of an ATA/ATAPI controller in an integrated RAID configuration, follow these steps:
When the test computer is turned off, complete the following assembly steps:
Install a boot-capable controller (not the test device) and hard disk drive, if the test devices do not support boot.
Attach the disks to the integrated test controller (Controller 1) according to the following table:
Controller type Controller 1 ATA RAID
One ATA hard disk drive on each supported channel
Attach an optical drive to the system, if one is not already attached.
Turn on the test system.
Set the system BIOS to support the S3 state.
Create two 60-GB RAID arrays on Controller 1.
If the controller does not support a configuration that includes two arrays, use a non-RAID disk instead of Array 2 for these procedures. For SCSI, create a third 60-GB RAID array (using any supported RAID level).
The RAID arrays on Controller 1 are RAID Array 1 and RAID Array 2.
Configure the RAID arrays according to the following table.
RAID levels that the test device supports RAID level for RAID Array 1 RAID level for RAID Array 2 0 only
0
0
1 only
1
1
5 only
5
5 or Non-RAID disk
0 and 1 only
1
0
0 and 5 only
5
0 or Non-RAID disk
1 and 5 only
5
1or Non-RAID disk
0, 1, and 10
10
1 or Non-RAID disk
0, 1, and 5
5
0 or Non-RAID disk
0, 1, 10, and 5
5
10 or Non-RAID disk
Turn on the test computer install the appropriate Windows operating system, and then configure the computer for your test network. The test network is the network that contains the Windows HLK Studio and Windows HLK Controller.
Install the appropriate Microsoft Windows operating system to a 36-GB NTFS volume on RAID Array 1, and then configure the computer for your test network. The test network is the network that contains the Windows HLK Studio and Windows HLK Controller. If the test controller is not bootable, install Windows to a separate hard disk drive on a bootable controller.
If it is necessary, install any drivers that a manufacturer supplies that the devices in the test system require.
Start Windows on the test computer.
To set the system page file and enable crashdump, do the following:
Click the Start button, right-click My Computer, and then click Properties.
Click the General tab, and then note the amount of RAM that the computer contains.
Click the Advanced tab (or click Advanced system settings in the left pane for Windows Vista, Windows 7, Windows 8, Windows Server 2008, Windows Server 2008 R2 or Windows Server 2012), and then, in the Performance area, click Settings.
Note
If you are prompted to enter administrative credentials or allow the action, enter the credentials or allow the action.
Click the Advanced tab, and then, in the Virtual Memory area, click Change.
Select Custom Size, and then enter a number in the Initial size (MB) box that is larger than the size of RAM that you noted in step b.
In the Maximum size (MB) text box, enter a maximum size value that is larger than the initial size that you entered in the Initial size (MB) box. (The maximum size is typically 1.5 to 2 times the initial size.)
Click Set, and then click OK two times.
Click OK, and then restart the computer to update the page file size.
Verify that the storage array is accessible from the test computer.
Copy the Windows symbol files to %SystemDrive%Symbols.
Install the Windows HLK client application on the test computer.
Use Windows HLK Studio to create a computer pool, and then move the test computer to that pool.
Non-RAID controller test configuration
To configure the test computer to test an ATA/ATAPI controller in a non-RAID configuration, follow these steps:
When the test computer is turned off, complete the following assembly steps:
Install a boot-capable controller (not the test device) and hard disk drive if the test devices do not support boot.
Install the test device (Controller 1).
Attach the disks to the test devices according to the following table.
Controller type Controller 1 Controller 2 ATA/ATAPI controllers
Primary Master: UDMA HDD (Disk 1)
Primary Subordinate: Optical recorder
Secondary Master: UDMA HDD (Disk 2)
Secondary Subordinate: ATA/ATAPI tape drive
N/A
Attach an optical drive to the system, if one is not already attached.
Turn on the test computer.
Set the system BIOS to support the S3 state.
Install the appropriate Microsoft Windows operating system onto disk 1. Use a newly created NTFS partition that has at least 36 GB of disk space. Then, configure the computer for your test network. The test network is the network that contains the Windows HLK Studio and Windows HLK Controller.
If you have to install a manufacturer-supplied device driver on the test computer, do this now.
Create three 4-GB partitions on Disk 2.
Use the following procedure to set the system page file and enable crashdump:
Click the Start button, right-click My Computer, and then click Properties.
Click the General tab, and then note the amount of RAM that the computer contains.
Click the Advanced tab (or click Advanced system settings in the left pane for Windows Vista, Windows 7, Windows 8, Windows Server 2008, Windows Server 2008 R2 or Windows Server 2012), and then, in the Performance area, click Settings.
Note
If you are prompted to enter administrative credentials or allow the action, enter the credentials or allow the action.
Click the Advanced tab, and then, in the Virtual Memory area, click Change.
Select Custom Size, and then enter a number in the Initial size (MB) box that is larger than the size of RAM that you noted in step b.
In the Maximum size (MB) text box, enter a maximum size value that is larger than the initial size that you entered in the Initial size (MB) box. (The maximum size is typically 1.5 to 2 times the initial size.)
Click Set, and then click OK two times.
Click OK, and then restart the computer to update the page file size.
Verify that the storage array is accessible from the test computer.
Copy the Windows symbol files to %SystemDrive%Symbols.
Install the Windows HLK client application on the test computer.
Use Windows HLK Studio to create a computer pool, and then move the test computer to that pool.